新聞
聯(lián)系我們
來(lái)源:http://n3462.cn/ 日期:2024-01-29
作為火災(zāi)自動(dòng)報(bào)警系統(tǒng)的控制中心,,火災(zāi)報(bào)警控制器具有火災(zāi)報(bào)警功能、火災(zāi)報(bào)警控制功能,、故障報(bào)警功能,、屏蔽功能、監(jiān)管功能,、自檢功能,、信息顯示與查詢功能及電源功能等。
As the control center of the automatic fire alarm system, the fire alarm controller has functions such as fire alarm, fire alarm control, fault alarm, shielding, supervision, self inspection, information display and query, and power supply.
(1)控制器能直接或間接地接收來(lái)自火災(zāi)探測(cè)器及其他火災(zāi)報(bào)警觸發(fā)器件的火災(zāi)報(bào)警信號(hào),,發(fā)出火災(zāi)報(bào)警聲,、光信號(hào),指示火災(zāi)發(fā)生部位,,記錄火災(zāi)報(bào)警時(shí)間,并予以保持,,直到手動(dòng)復(fù)位,。控制器具有專用火警總指示燈,,控制器處于火災(zāi)報(bào)警狀態(tài)時(shí),,火警示燈點(diǎn)亮?;馂?zāi)報(bào)警信號(hào)能手動(dòng)消防,,當(dāng)再次有火災(zāi)報(bào)警信號(hào)輸入時(shí),能再次啟動(dòng),。
(1) The controller can directly or indirectly receive fire alarm signals from fire detectors and other fire alarm triggering devices, emit fire alarm sound and light signals, indicate the location of the fire, record the fire alarm time, and maintain it until manually reset. The controller has a dedicated fire alarm main indicator light, which lights up when the controller is in a fire alarm state. The fire alarm signal can be manually used for firefighting, and it can be restarted when there is another fire alarm signal input.
(2)控制器可設(shè)置控制輸出,,用于火災(zāi)報(bào)警傳輸設(shè)備和消防聯(lián)動(dòng)設(shè)備等設(shè)備的控制,每一控制輸出有對(duì)應(yīng)的手動(dòng)直接控制按鈕,。
(2) The controller can set control outputs for the control of fire alarm transmission equipment and fire linkage equipment, and each control output has a corresponding manual direct control button.
(3)故障報(bào)警功能:控制器設(shè)專用故障報(bào)警總指示燈,,無(wú)論控制器處于何種狀態(tài),,只要有故障信號(hào)存在,該故障總指示燈點(diǎn)亮,。當(dāng)控制器內(nèi)部,、控制器與其連接的部件間發(fā)生故障時(shí),控制器能在100S內(nèi)發(fā)出與火災(zāi)報(bào)警信號(hào)有明顯區(qū)別的故障聲,、光信號(hào),,故障聲信號(hào)能手動(dòng),如再有故障信號(hào)輸入時(shí),,能再次啟動(dòng),,故障光信號(hào)能保持故障排除。
(3) Fault alarm function: The controller is equipped with a dedicated fault alarm main indicator light. Regardless of the state of the controller, as long as there is a fault signal, the fault main indicator light will light up. When there is a fault inside the controller or between the controller and its connected components, the controller can emit a fault sound and light signal that is significantly different from the fire alarm signal within 100 seconds. The fault sound signal can be manually eliminated. If there is another fault signal input, it can be restarted and the fault light signal can be maintained until the fault is eliminated.
(4)控制器設(shè)專用屏蔽總指示燈,,無(wú)論控制器處于何種狀態(tài),,只要有屏蔽存在,該屏蔽總指示信號(hào)燈點(diǎn)亮,。
(4) The controller is equipped with a dedicated shielding main indicator light. Regardless of the state of the controller, as long as there is shielding present, the shielding main indicator light will light up.
(5)監(jiān)管功能(動(dòng)作):控制器設(shè)專用監(jiān)管報(bào)警狀態(tài)總指示燈,,無(wú)論控制器處于何種,只要有監(jiān)管信號(hào)輸入,,該監(jiān)管報(bào)警狀態(tài)總指示燈點(diǎn)亮,。
(5) Regulatory function (action): The controller is equipped with a dedicated regulatory alarm status indicator light. Regardless of the controller's status, as long as there is a regulatory signal input, the regulatory alarm status indicator light will light up.
當(dāng)有監(jiān)管信息輸入時(shí),控制器能在100S內(nèi)發(fā)出與火災(zāi)報(bào)警信號(hào)有明顯區(qū)別的監(jiān)管報(bào)警聲,、光信號(hào),;聲信號(hào)僅能手動(dòng),漢有冷的的監(jiān)管信號(hào)輸入時(shí)能再次啟動(dòng),;光信號(hào)能保持手支復(fù)位,。如果監(jiān)管信號(hào)仍存在,復(fù)位后監(jiān)管報(bào)警狀態(tài)能保持或在20S內(nèi)重新建立,??刂破髂茱@示所有監(jiān)管信號(hào),當(dāng)天能同時(shí)顯示時(shí)可手動(dòng)查詢,。
When there is regulatory information input, the controller can emit regulatory alarm sound and light signals that are significantly different from fire alarm signals within 100 seconds; The sound signal can only be manually eliminated, and Han Youleng's supervision signal can be restarted when input; The optical signal can be maintained until the hand is reset. If the regulatory signal still exists, the regulatory alarm status can be maintained or re established within 20 seconds after resetting. The controller can display all regulatory signals and can manually query them when they can be displayed simultaneously on the same day.
(6)自檢功能:控制器能檢查本機(jī)的火災(zāi)報(bào)警功能稱為自檢,。控制器在執(zhí)行自檢功能期間,,受其控制的外接設(shè)備和輸出接點(diǎn)均不動(dòng)作,。控制器自檢超過(guò)1分種或其不能自動(dòng)停止時(shí),,控制器的自檢功能不影響非自檢部位,、探測(cè)區(qū)和控制器本身的火災(zāi)報(bào)警功能。
(6) Self check function: The controller's ability to check the fire alarm function of the machine is called self check. During the self check function of the controller, the external devices and output contacts controlled by it do not operate. When the self-test of the controller exceeds 1 minute or it cannot automatically stop, the self-test function of the controller does not affect the fire alarm function of non self-test parts, detection areas, and the controller itself.
(7)信息顯示與查詢功能:控制器信息顯示按火災(zāi)報(bào)警,、監(jiān)管報(bào)警及其它狀態(tài)順序由高低排列信息顯示等級(jí),,高等級(jí)的狀態(tài)信息優(yōu)先顯示,,低等級(jí)狀態(tài)信息顯示不應(yīng)影響高等級(jí)信息顯示,顯示的信息與對(duì)應(yīng)的狀態(tài)一致且易于辨識(shí),。當(dāng)控制器處于某一高等級(jí)狀態(tài)顯示時(shí),,能通過(guò)手動(dòng)操作查詢其它低等級(jí)狀態(tài)信息,和狀態(tài)信息不交替顯示,。
(7) Information display and query function: The controller displays information in descending order of fire alarm, regulatory alarm, and other status. High level status information is displayed first, while low level status information should not affect the display of high level information. The displayed information should be consistent with the corresponding status and easy to identify. When the controller is in a certain high-level status display, it can manually query other low-level status information without alternating with the status information.
(8)電源功能:主機(jī)控制器具有主電源和備用電源轉(zhuǎn)換裝置,,當(dāng)主電源斷電時(shí),能自動(dòng)轉(zhuǎn)換到備用電源,;主電源恢復(fù)時(shí),,能自動(dòng)轉(zhuǎn)換到主電源??刂破饔兄?、備電源工作狀態(tài)指示,主備電源轉(zhuǎn)換不不使控制器產(chǎn)生誤動(dòng)作,。
(8) Power function: The host controller has a main power and backup power conversion device, which can automatically switch to the backup power when the main power is cut off; When the main power supply is restored, it can automatically switch to the main power supply. The controller has the indication of the working status of the main and backup power supplies, and the conversion of the main and backup power supplies does not cause the controller to malfunction.
本文由川消友情奉獻(xiàn).更多有關(guān)的知識(shí)請(qǐng)點(diǎn)擊:http://n3462.cn我們將用真誠(chéng)的態(tài)度.為您提供為的服務(wù).更多有關(guān)的知識(shí)我們將會(huì)陸續(xù)向大家奉獻(xiàn).敬請(qǐng)期待.
This article is dedicated by Chuanxiao Youqing. For more related knowledge, please click: http://n3462.cn We will provide you with comprehensive service with a sincere attitude. We will gradually contribute more relevant knowledge to everyone. Stay tuned