當(dāng)前位置:首頁(yè) > 新聞中心自動(dòng)跟蹤定位射流滅火系統(tǒng)應(yīng)符合這樣的要求,!

自動(dòng)跟蹤定位射流滅火系統(tǒng)應(yīng)符合這樣的要求!

來(lái)源:http://n3462.cn/ 日期:2023-05-23

大空間場(chǎng)所適合安裝消防水炮滅火系統(tǒng),,這已經(jīng)在眾多項(xiàng)目工程中得以證明,,那么在選型及安裝方面,一直都是大家所關(guān)注的幾個(gè)點(diǎn),,比如說(shuō)哪類場(chǎng)所要用多大流量的水炮,,哪類場(chǎng)所需要用防爆消防炮等等,具體這些在規(guī)范中有無(wú)說(shuō)明呢,?今天川消小編就結(jié)合新規(guī)范內(nèi)容來(lái)給大家講解一下吧,。
Large space locations are suitable for installing fire water cannon fire extinguishing systems, which has been proven in many project projects. Therefore, in terms of selection and installation, it has always been a few points of concern, such as which type of location needs to use a large flow of water cannon, which type of location needs to use explosion-proof fire cannon, and so on. Is there a specific specification for these? Today, the editor of Chuanxiao will explain it to everyone in conjunction with the new standard content.
在新規(guī)范《消防設(shè)施通用規(guī)范》GB55036-2022中,將固定消防炮和自動(dòng)跟蹤定位射流滅火系統(tǒng)的內(nèi)容統(tǒng)一規(guī)整在了一起,,這樣對(duì)于滅火系統(tǒng)的設(shè)計(jì)有了更為清晰條例的匯總,,其中關(guān)于大空間場(chǎng)所選擇消防水炮滅火系統(tǒng)的規(guī)定,主要有以下幾個(gè)方面,。
In the new standard "General Specification for Fire Protection Facilities" GB55036-2022, the content of fixed fire monitors and automatic tracking and positioning jet fire extinguishing systems has been unified and organized together, which provides a clearer summary of regulations for the design of fire extinguishing systems. Among them, there are mainly the following aspects regarding the selection of fire water monitor fire extinguishing systems in large space places.
1,、自動(dòng)消防炮滅火系統(tǒng)中單臺(tái)炮的流量,對(duì)于民用建筑,,不應(yīng)小于20L/s;對(duì)于工業(yè)建筑,,不應(yīng)小于30L/s。
1. The flow rate of a single monitor in the automatic fire extinguishing system should not be less than 20L/s for civil buildings; For industrial buildings, it should not be less than 30L/s.
2,、持續(xù)噴水時(shí)間不應(yīng)小于1.0h,。
2. The continuous water spraying time should not be less than 1.0h.
3、系統(tǒng)應(yīng)具有自動(dòng)控制,、消防控制室手動(dòng)控制和現(xiàn)場(chǎng)手動(dòng)控制的啟動(dòng)方式,。消防控制室手動(dòng)控制和現(xiàn)場(chǎng)手動(dòng)控制相對(duì)于自動(dòng)控制應(yīng)具有優(yōu)先權(quán)。
3. The system should have automatic control, manual control in the fire control room, and on-site manual control for startup. Manual control in the fire control room and on-site manual control should have priority over automatic control.
川消
4,、自動(dòng)消防炮滅火系統(tǒng)和噴射型自動(dòng)射流滅火系統(tǒng)在自動(dòng)控制狀態(tài)下,,當(dāng)探測(cè)到火源后,應(yīng)少有2臺(tái)滅火裝置對(duì)火源掃描定位和少1臺(tái)且多2臺(tái)滅火裝置自動(dòng)開(kāi)啟射流,,且射流應(yīng)能到達(dá)火源,。
4. The automatic fire monitor fire extinguishing system and the jet type automatic jet fire extinguishing system should be under automatic control. When a fire source is detected, at least two fire extinguishing devices should scan and locate the fire source, and at least one and two more fire extinguishing devices should automatically start the jet, and the jet should be able to reach the fire source.
5、噴灑型自動(dòng)射流滅火系統(tǒng)在自動(dòng)控制狀態(tài)下,,當(dāng)探測(cè)到火源后,對(duì)應(yīng)火源探測(cè)裝置的滅火裝置應(yīng)自動(dòng)開(kāi)啟射流,,且其中應(yīng)少有一組滅火裝置的射流能到達(dá)火源,。
5. In the automatic control state of the spray type automatic jet fire extinguishing system, when a fire source is detected, the fire extinguishing device corresponding to the fire source detection device should automatically start the jet, and at least one set of fire extinguishing devices should have the jet that can reach the fire source.
規(guī)范前四條說(shuō)的都是大家所熟知的消防水炮滅火系統(tǒng),第五條則是對(duì)于大空間智能噴頭的規(guī)定,,如果有些場(chǎng)所受到高度或者內(nèi)部結(jié)構(gòu)的影響,,不適宜選擇消防水炮滅火系統(tǒng)的話,,就可以考慮大空間智能噴頭,這一點(diǎn)在很多的項(xiàng)目工程設(shè)計(jì)中就有體現(xiàn),。還有什么要點(diǎn)要了解的就來(lái)我們網(wǎng)站http://n3462.cn咨詢吧,!
The first four articles of the standard all refer to the well-known fire water cannon fire extinguishing system, while the fifth article specifies the regulations for large space intelligent nozzles. If some places are affected by height or internal structure and it is not suitable to choose a fire water cannon fire extinguishing system, large space intelligent nozzles can be considered, which is reflected in many project engineering designs. If you have any other key points to learn, please come to our website http://n3462.cn Consult!